Calibration Instrument

ctptcalibrationsystem

1) Regulation: manual

2) Rated capacity: 5kVA,10kVA,15kVA,20kVA,30kVA

3) Current measurement range : 5A-1000A,5A-2000A,5A-3150A,5A-5000A

4) Voltage measuring range : 3kV,6kV,10kV,15kV,20kV,35kV,110kV,220kV

5) Standard transformer accuracy: 0.01,0.02,0.05

6) Regulation system provides coarse and fine tuning.

7) Open-circuit demagnetization and closed-circuit demagnetization

Note:

1) Testing volt-ampere characteristic of current transformer and no-load loss of voltage transformer can be added to the system.

2) Customized software is available with a little charge

burdencalibrator

BFZ CT/PT Burden Calibrator

- Product overview:

BFZ CT/PT calibrator is designed to test the accuracy of current/voltage transformer burdens.

It has a wide measuring range and an excellent linearity. It is idea for transformer manufacturers and test labs.

- Test object : impedance of current transformer burden , admittance of voltage transformer burden

- Measuring range:

  Active part measuring range : 0.0001—199.9 ohm (mS),

  Reactive part measuring range : 0.0001—199.9 ohm (mS)

- Resolution: active part : 0.0001 ohm (mS), reactive part : 0.0001 ohm (mS)

- Accuracy local seo services : ±0.5%±2 digits

- Dimension: 460 X 380 X 160mm

- Weight: york hotels less than 15kg

 PortableCalibrator

HES-1B internet marketing services CT/PT Accuracy Tester

- Testing object: S-level current transformer, general current transformer,voltage transformer

- Testing item: ratio difference, phase difference, impedance, admittance of the transformer, etc

- Rated current: 5A,1A ( or other rating student loan calculator values)

- Rated voltage: 100V,100/ ?3V,100/3V, 110V, 220V or other rating values

- Measuring range:

  Ratio difference measuring range: 0.0001%-19.99%

  Phase difference measuring range : 0.01 ' -900 '

-Resolution: refused credit ratio difference: 0.0001% phase difference: 0.01 '

- Measuring accuracy: ±1%±1 digit

- Consumed power: less than 20VA

- Dimension: 390 x 300 x 160 mm

- Weight: 5kg

 CTcalibrator

HES-1W low current CT accuracy test set

- Testing objects: mA level current transformer, ratio difference, phase difference

- Rated current: 1mA-99mA

- Measuring range:

  search engine optimization Ratio difference measuring range : 0.0001%-19.99%

  Phase difference measuring range : 0.01 ' -900 '

- Resolution: ratio difference:0.0001% phase difference:0.01 '

- Measuring accuracy: ±2%±1 digit

- Over load capacity: 5 times

- Load professional seo services provided for testing (ohm): 0, 5,10,15,20,25,50,100,200,300,500  (Extendable)

- Consumed power: less than 20VA

- Dimension: 460 x 380 x 160 mm

- Weight: 10kg

Additional information